ELECTRIC MOTORS |
 |
| |
|
| |
 |
| |
A complete range of AC motors developed for gearmotor duty that will exceed expectations
The IEC-normalized BN motors comply with all the applicable international standards, including the EMC and LV Directives. They are available in the 0.06 - 30 kW range in the foot and the flange mounting version, the latter in both the IM B5 and the IM B14 configuration. Single and dual pole version available with generally, three brake options offered, one DC and two AC supply, lending further flexibility to the system. Finally, all motors are inverter duty.
|
|
|
 |
|
|
BN series AC motors

| Type |
kW
|
|
|
| BN
56A |
0,06
|
|
|
| BN 56B |
0,09
|
|
|
| BN 63A |
0,12
|
|
|
| BN 63B |
0,18
|
|
|
| BN 63C |
0,25
|
|
|
| BN 71A |
0,25
|
|
|
| BN 71B |
0,37
|
|
|
| BN 71C |
0,55
|
|
|
| BN 80A |
0,55
|
|
|
| BN 80B |
0,75
|
|
|
| BN 80C |
1,1
|
|
|
| BN 90S |
1,1
|
|
|
| BN 90LA |
1,5
|
|
|
| BN 90LB |
1,85
|
|
|
| BN
100LA |
2,2
|
|
|
| BN
100LB |
3
|
|
|
| BN 112M |
4
|
|
|
| BN 132S |
5,5
|
|
|
| BN
132MA |
7,5
|
|
|
| BN
132MB |
9,2
|
|
|
| BN
160MR |
11
|
|
|
| BN 160M |
15
|
|
|
| BN 180M |
18,5
|
|
|
| BN 180L |
22
|
|
|
| BN 200L |
30
|
|
|
kW rating (4 pole)
0,06 kW ... 30kW
Frame Sizes
25 nos
Pole Numbers
2, 4, 6, 8, 2/4, 2/8, 2/12, 4/6, 4/8
Mounting Options
Foot IM B3
Flange Im B5 and IM B14
Operation
50 Hz and 60 Hz
Compliance
CEE 73/23 (LVD) and CEE 89/336 (EMC)
Inverter Duty
All Frame Sizes
Housing
Cast Alluminium
Main Brake Features
DC and AC supply
Faster Brake Engage/Disengage through Electronically
Controlled AC/DC Rectifier type SB, NBR, SBR (option)
Main Options
Thermistors and Thermostates sensor
Separate Supply Forced Ventilation
Line Driver and Push-Pull Incremental Encoder
CSA and UL Approved Design
|
|
|
 |
|
|
 |
| »
SALES CATALOGUE
|
 |
|
|
|
|
|
|
 |
| » OWNER'S MANUAL AND SPARE PARTS LIST
|
 |
|
|
|
|
|
|
 |
| » INSTALLATION, USE AND SERVICE MANUAL
|
 |
|
|
|
|
|
|
|
|
 |
|
|
A comprehensive range of permanent magnet DC motors
The motors of the BC series are the simple, proven and economical
solution to the requirements of DC drives. The materials and the
design concepts exploited allow the use of BC motors under the
severest duty and with 4-quadrants thyristor converters. Motors
can be operated in the –20 to +40 °C temperature range and are
IP54 protected and class F isolated.
|
|
|
 |
|
|
BC series DC motors

| Type |
Torque Nm
|
|
|
| BC
110 |
0,3
|
|
|
| BC 120 |
0,8
|
|
|
| BC 140 |
1,4
|
|
|
| BC 220 |
0,9
|
|
|
| BC 240 |
1,2
|
|
|
| BC 270 |
2,2
|
|
|
| BC 310 |
4,5
|
|
|
Torque Range
0,3 Nm ... 4,5 Nm
Speed
1.500, 2.000, 3.000 min-1
Supply
12, 24, 36, 48,65, 110, 180, Vdc
Configurations
IM B5 and IM B14 Flange Mount
Ventilation
BC110 ... BC140 non-ventilated
BC220 ... BC310 TEFC
|
|
|
 |
|
|
System advantage
The NFF series is compact and easy to install, these units are completely closed (IP54 protection) and do not need any maintenance or adjustment of magnetic gap thanks to the special system for taking up any backlash caused by wear and
tear.
|
|
|
 |
|
|
NFF series Clutch-Brake Units

| Type |
Torque Nm
|
|
|
| NFF
07 |
8
|
|
|
| NFF 09 |
15
|
|
|
| NFF 11 |
30
|
|
|
| NFF 14 |
75
|
|
|
Torque Range
8 Nm ... 75 Nm
Max. Inputed Speed
3.000 min-1
Max. Work per each Braking
7 KJ ... 55 kJ
Max. Work per Hour
260 KJ/h ... 360 kJ/h
Max. Work between service
280 MJ ... 1220 MJ
Installation
Both Horiontal and Vertical Permitted
Input and Output Configuration
Both Solid and Hollow Shaft Available
Mounting Options:
Both Horiontal and Vertical Permitted
Foot Available
IM B5 Flange Available
IM B14 Flange Available
|
|
|
 |
|
| »
COD. BC0054 - REV 0
|
 |
|
|
|
|
|
|
|
|
 |
|
|
The proven and valuable choice when it comes to DC servomotors
The motors of the BCS series are of the permanent magnet type and will allow an approx. 400% peak torque over the rated torque.
The particular construction guarantees extreme smoothness in operation, even at low
speed.
|
|
|
|
|
 |
|
|
BCS series DC servomotors

| Type |
Torque Nm
|
|
|
| BCS
10 |
0,05
|
|
|
| BCS 20 |
0,4
|
|
|
| BCS 30 |
0,9
|
|
|
| BCS 40 |
1,4
|
|
|
| BCS 50 |
1,5
|
|
|
| BCS 60 |
3,0
|
|
|
| BCS 70 |
4,5
|
|
|
| BCS 80 |
7,7
|
|
|
Locked Rotor Torque
0,05 Nm ... 7,7 Nm
Speed
1.500, 2.000, 3.000, 4.000 min-1
Rated Voltage
24 ... 180 Vdc
Momentary Peak Torque
400/500% over LRT
Degree of Protection
IP54
Configurations
IM B5 and IM B14 Flange Mount
Options
Failsafe DC Brake
Tacho-generator
|
|
|
 |
|
|
BS series Single-phase induction motors

| Type |
Torque Nm
|
|
|
| BS 56A |
0,06
|
|
|
| BS 56B |
0,09
|
|
|
| BS 63A |
0,12
|
|
|
| BS 63B |
0,18
|
|
|
| BS 71A |
0,25
|
|
|
| BS 71B |
0,37
|
|
|
| BS 80A |
0,55
|
|
|
| BS 80B |
0,75
|
|
|
| BS 90S |
1,1
|
|
|
| BS 90L |
1,5
|
|
|
kW ratings
0,06 … 1,5 kW
Frame sizes
56A to 90L
Poles
4
Mounting
Flange mounting IM B5 and IM B14
Frequency
50 and 60 Hz
European Norms
CEE 73/23 (LVD) and CEE 89/336 (EMC)
Housing
Cast Aluminium
Main options
Starting and run capacitors
Bimetal thermal protector
Balanced winding
|
|
|
 |
|
|
 |
| »
SALES CATALOGUE
|
 |
|
|
|
|
|
|
 |
| »
OWNER'S MANUAL
|
 |
|
|
|
|
|
|
|
Brake motors
MGM brake motors are asynchronous three-phase totally enclosed fan cooled motors. The motors brake in case of power supply failure ensuring further to a precise stop and a quick braking action. the security of a sudden intervention in case of an unintentional power supply failure (f.e. power supply blackout, equipment
failure).
The braking action is obtained without axial sliding of the shaft and provides equal braking torque in both directions of rotation.
MGM brake motors are specially suitable to be used with lifting and translating machines, tooling machinery, automatic and transfer machinery in textile, ceramic and packing fields and in all situation where precision and quickness in braking are required, or to cut production cycles in fixed spaces and times
|
|

 |
| |
 |
| |
SMI MOTORS
SMI series is made up of three-phase asynchronous electric motors with integrated frequency converter. Power range is between 0,37 kW and 4 kW, while motor axis height is between 71 mm and 112 mm. Unit is made up of a high-efficiency three-phase asynchronous electric motor and a compact frequency inverter placed at the motor end opposite to the control end. The basic construction is closed, externally ventilated with IP 55 protection class. SMI motor offers a wide range of overload capacity and a high thermal reserve; the insulating materials are class F
.
|
|
 |
| |
 |
| |
|
|
| |
 |
| |
|
|
|
 |
| |
Tecnica
Industriale Srl
S.S. 98 Km 80.176 - 70026 Modugno (Ba) - Italy
Tel +39 0805367090 - Fax +39 0805367091
E-mail: info@tecnicaindustriale.it
|
 |
|
| |
 |
| |
|
|
|